1 / 1
60W Slim Lightingbox Power Supply IP20
Model: CLL60-W1V
Rated Power: 60W
Output Voltage: 12V/24V
IP Grade: 20
Certificate: CE ROHS
Warranty: 2 year
Product Details
| Product Code | CLL60-W1V12 | CLL60-W1V24 | |||
| Output | DC Voltage | 12V | 24V | ||
| Voltage tolerance | ±2% | ±2% | |||
| Rated Current | 5A | 2.5A | |||
| Rated Power | 60W | 60W | |||
| Max Power | 68W | 68W | |||
| Ripple & Noise | ≤100mVp-p | ≤150mVp-p | |||
| Set-up, Rise, Hold-up Time | 1500ms, 30ms / 230VAC | ||||
| Input | Input voltage range | 100-240 VAC | |||
| AC Current | 0.5A / 230VAC | ||||
| Efficiency | 85% | ||||
| Quiescent current | ≤100mA/230VAC | ||||
| Protection | Over Load | Above 110%-150% of rated power | |||
| Shut-down output voltage, auto recovery after fault condition is removed | |||||
| Over Voltage | Above Max. Voltage (105% of rated voltage) | ||||
| Shut-down output voltage, auto recovery after fault condition is removed | |||||
| Over Temperature | Over 130°C detected on main IC control | ||||
| Shut-down output voltage, auto recovery after fault condition is removed | |||||
| Ambiant | Working Temp. & humidity | “-40°C~+60°C, 20%~90%RH | |||
| Storage temp. & humidity | “-40°C~+85°C, 10%~95%RH | ||||
| Withstand voltage | I/ P-O/ P: 3KVAC/ 1min; I/ P-F/G: 1.5KVAC/ 1min;O/ P-F/G: 0.5KVAC/ 1min; | ||||
| Tesings | Safety | GB4943 ;IEC60950-1; EN60950-1 | |||
| EMC | EN55032:2015/AC:2016 EN61000-3-2:2014 EN61000-3-3:2013 |
||||
| LVD | EN60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 | ||||
| Other | Casing Material | Aluminum | |||
| Cooling Method | Free air cooling | ||||
| Demension(L*W * H) | 316* 18* 15mm (L*W* H) | ||||
| Weight | 0.15kg/ 100pcs/18kg/CTN | ||||
| Note | 1, The above mentioned data were measured at 230VAC input and 25°C. 2, Dis-connect the AC input before checking any mal-phenomenons. 3, Make sure the INPUT&OUPUT were in right situation before connected to power supply. 4, Datesheet for reference only. We suggest you take sampling before mass orders. |
||||